1.
Cancer Med ; 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38189631

RESUMO

BACKGROUND: Melanoma, the most lethal skin cancer type, occurs more frequently in Parkinson's disease (PD), and PD is more frequent in melanoma patients, suggesting disease mechanisms overlap. α-synuclein, a protein that accumulates in PD brain, and the oncogene DJ-1, which is associated with PD autosomal recessive forms, are both elevated in melanoma cells. Whether this indicates melanoma progression or constitutes a protective response remains unclear. We hereby investigated the molecular mechanisms through which α-synuclein and DJ-1 interact, suggesting novel biomarkers and targets in melanoma. METHODS: The Cancer Genome Atlas (TCGA) expression profiles derived from UCSC Xena were used to obtain α-synuclein and DJ-1 expression and correlated with survival in skin cutaneous melanoma (SKCM). Immunohistochemistry determined the expression in metastatic melanoma lymph nodes. Protein-protein interactions (PPIs) and molecular docking assessed protein binding and affinity with chemotherapeutic drugs. Further validation was performed using in vitro cellular models and ELISA immunoassays. RESULTS: α-synuclein and DJ-1 were upregulated in primary and metastatic SKCM. Aggregated α-synuclein was selectively detected in metastatic melanoma lymph nodes. α-synuclein overexpression in SK-MEL-28 cells induced the expression of DJ-1, supporting PPI and a positive correlation in melanoma patients. Molecular docking revealed a stable protein complex, with differential binding to chemotherapy drugs such as temozolomide, dacarbazine, and doxorubicin. Parallel reduction of both proteins in temozolomide-treated SK-MEL-28 spheroids suggests drug binding may affect protein interaction and/or stability. CONCLUSION: α-synuclein, together with DJ-1, may play a role in melanoma progression and chemosensitivity, constituting novel targets for therapeutic intervention, and possible biomarkers for melanoma.

2.
BMC Cancer ; 23(1): 174, 2023 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-36809974

RESUMO

BACKGROUND: Gliomas are the most common brain tumours with the high-grade glioblastoma representing the most aggressive and lethal form. Currently, there is a lack of specific glioma biomarkers that would aid tumour subtyping and minimally invasive early diagnosis. Aberrant glycosylation is an important post-translational modification in cancer and is implicated in glioma progression. Raman spectroscopy (RS), a vibrational spectroscopic label-free technique, has already shown promise in cancer diagnostics. METHODS: RS was combined with machine learning to discriminate glioma grades. Raman spectral signatures of glycosylation patterns were used in serum samples and fixed tissue biopsy samples, as well as in single cells and spheroids. RESULTS: Glioma grades in fixed tissue patient samples and serum were discriminated with high accuracy. Discrimination between higher malignant glioma grades (III and IV) was achieved with high accuracy in tissue, serum, and cellular models using single cells and spheroids. Biomolecular changes were assigned to alterations in glycosylation corroborated by analysing glycan standards and other changes such as carotenoid antioxidant content. CONCLUSION: RS combined with machine learning could pave the way for more objective and less invasive grading of glioma patients, serving as a useful tool to facilitate glioma diagnosis and delineate biomolecular glioma progression changes.


Assuntos
Neoplasias Encefálicas , Glioblastoma , Glioma , Humanos , Análise Espectral Raman/métodos , Glicosilação , Glioma/patologia , Neoplasias Encefálicas/patologia , Glioblastoma/patologia , Gradação de Tumores
3.
J Hazard Mater ; 448: 130862, 2023 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-36708696

RESUMO

Given the significant presence of the carcinogenic Cr(VI) in arc welding fumes from stainless steels, it is also important, in addition to estimating the Cr(VI) levels, to identify Cr(VI) compounds, as it throws light on the mechanistic pathways towards fume formation. FTIR data is presented in this paper for arc welding fumes collected from Manual Metal Arc Welding (MMA), Flux Cored Arc Welding (FCAW) and Solid Wire Welding (Metal Inert/ Active Gas Welding [MIG/ MAG]). For MMA and FCAW samples, clear spectra corresponding to Na, K, dichromates was observed at wave number of around 725-740 cm-1 and at 890-900 cm-1. Chromate species were also observed at around 850-855 cm-1, as was evidence of CrO3 (chromium trioxide) too (950-970 cm-1). The identification of these compounds was done by carefully identifying the Cr-O-Cr anti-symmetric vibrations, the symmetric stretching of the CrO4 tetrahedra, and the stretching vibrations of the planar CrO3 structure for the chromium trioxide. All the above compounds were volatile, and present as nanoparticles in welding fumes, thereby potentially causing significant harm to the welders. Additionally, crystalline phases (Fe-Mn spinels) were also observed through powder XRD, and the data was compared with ion chromatography estimates for Cr(VI) and found to be consistent.

4.
Sci Rep ; 12(1): 19868, 2022 11 18.
Artigo em Inglês | MEDLINE | ID: mdl-36400876

RESUMO

Glioblastoma is the most aggressive form of brain cancer, presenting poor prognosis despite current advances in treatment. There is therefore an urgent need for novel biomarkers and therapeutic targets. Interactions between mucin 4 (MUC4) and the epidermal growth factor receptor (EGFR) are involved in carcinogenesis, and may lead to matrix metalloproteinase-9 (MMP9) overexpression, exacerbating cancer cell invasiveness. In this study, the role of MUC4, MMP9, and EGFR in the progression and clinical outcome of glioma patients was investigated. Immunohistochemistry (IHC) and immunofluorescence (IF) in fixed tissue samples of glioma patients were used to evaluate the expression and localization of EGFR, MMP9, and MUC4. Kaplan-Meier survival analysis was also performed to test the prognostic utility of the proteins for glioma patients. The protein levels were assessed with enzyme-linked immunosorbent assay (ELISA) in serum of glioma patients, to further investigate their potential as non-invasive serum biomarkers. We demonstrated that MUC4 and MMP9 are both significantly upregulated during glioma progression. Moreover, MUC4 is co-expressed with MMP9 and EGFR in the proliferative microvasculature of glioblastoma, suggesting a potential role for MUC4 in microvascular proliferation and angiogenesis. The combined high expression of MUC4/MMP9, and MUC4/MMP9/EGFR was associated with poor overall survival (OS). Finally, MMP9 mean protein level was significantly higher in the serum of glioblastoma compared with grade III glioma patients, whereas MUC4 mean protein level was minimally elevated in higher glioma grades (III and IV) compared with control. Our results suggest that MUC4, along with MMP9, might account for glioblastoma progression, representing potential therapeutic targets, and suggesting the 'MUC4/MMP9/EGFR axis' may play a vital role in glioblastoma diagnostics.


Assuntos
Glioblastoma , Glioma , Humanos , Mucina-4/metabolismo , Metaloproteinase 9 da Matriz/metabolismo , Glioblastoma/diagnóstico , Glioblastoma/metabolismo , Prognóstico , Glioma/diagnóstico , Receptores ErbB/metabolismo , Biomarcadores
5.
Phys Chem Chem Phys ; 23(36): 20478-20488, 2021 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-34498634

RESUMO

Time-resolved observations have been made of the formation of vibrationally excited NO X 2Π (v') following collisional quenching of NO A 2Σ+ (v = 0) by NO X 2Π (v = 0). Two time scales are observed, namely a fast production rate consistent with direct formation from the quenching of the electronically excited NO A state, together with a slow component, the magnitude and rate of formation of which depend upon NO pressure. A reservoir state formed by quenching of NO A 2Σ+ (v = 0) is invoked to explain the observations, and the available evidence points to this state being the first electronically excited state of NO, a 4Π. The rate constant for quenching of the a 4Π state to levels v' = 11-16 by NO is measured as (8.80 ± 1.1) × 10-11 cm3 molecule-1 s-1 at 298 K where the error quoted is two standard deviations, and from measurements of the increased formation of high vibrational levels of NO(X) by the slow process we estimate a lower limit for the fraction of self-quenching collisions of NO A 2Σ+ (v = 0) which lead to NO a 4Π as 19%.

6.
J Forensic Sci ; 66(6): 2424-2437, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34363402

RESUMO

One of the first challenges that crime scene examiners have is determining if a substance is blood before performing analysis. Conventional methods of detecting blood involve the use of chemicals and different wavelengths of light in tandem with digital photography. However, these methods are destructive or provide false positives. Visible wavelength hyperspectral imaging (HSI) is a noncontact blood detection method that has been proven to provide accurate and reliable results. A novel application of this technique has been used for the detection and positive identification of bloodstained footwear marks, of different dilutions ranging from undiluted to 1:50 with distilled water, and on a range of substrates, and colors. Comparisons between HSI and conventional digital photography were made using a grading scale and analyzed using Mann-Whitney U-tests. The HSI technique was able to detect a statistically significant greater amount of tread detail on white tiles, laminate, carpet, and blue tiles compared with the digital photography technique, which was only superior on black tiles. Critically, the HSI technique was also able to determine that the footwear marks were made in blood. These results show that HSI will be useful in forensic investigations, where it is known that the perpetrator has walked through the victim's blood and left a trail of footwear marks at the crime scene. Even if the perpetrator had time to clean up afterward resulting in diluted stains, HSI would still be able to detect bloodstained footwear marks with a greater amount of detail compared with digital photography.


Assuntos
Manchas de Sangue , Imageamento Hiperespectral , Processamento de Imagem Assistida por Computador , Fotografação , Sapatos , Ciências Forenses/métodos , Humanos
7.
ACS Omega ; 6(24): 15674-15685, 2021 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-34179611

RESUMO

Most fractured carbonate reservoirs are characterized by a highly permeable fracture zone surrounded by a low-permeability oil-wet matrix. These features make the displacement of oil from the matrix into the fracture zone almost impossible during water flooding. This paper presents the results of flooding with the polymer polyacrylamide (PAM) and the biopolymer xanthan gum (XG) in combination with a biosurfactant to enhance water imbibition into oil-wet fractured carbonate rocks. Core flooding experiments were conducted on induced horizontally fractured (at 180°) carbonate cores in room conditions (20 ± 2 °C). The polymer or biopolymer was used to plug the fracture zones, while the biosurfactant was added to the system to alter the wettability state of the rock matrix from oil-wet to water-wet. Rock surface characterization before and after core flooding was conducted using scanning electron microscopy (SEM). The results indicate that PAM flooding led to a higher reduction of 35.6% in fracture-matrix permeability than that with XG at 18.3%. The monitoring of oil production also showed that ultimate oil recovery levels from oil-wet fractured carbonate cores for the aforementioned systems were 16 and 8.7%, respectively, which can be attributed to the drive mechanisms of temporary fracture plugging as well as mobility ratio improvement due to the polymer and wettability alteration by the biosurfactant. SEM images confirm the proposed mechanisms, where the presence of the polymer/biopolymer followed by the biosurfactant can be detected at the rock surface as a result of chemical flow through the system.

8.
Anal Chim Acta ; 1155: 338352, 2021 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-33766322

RESUMO

Development of biosimilars is costly, where glycan analysis is a significant constraint on time and money. This paper provides an in-depth characterisation of several novel recombinant prokaryotic lectins (RPLs), developed through directed evolution, displaying specific binding activities to α-mannose, ß-galactose, fucose and sialic acid residues, tested against major biosimilar targets. The binding characterisation of all lectins was performed employing the principles of bio-layer interferometry (BLI), with help of the streptavidin-coated sensor with the biotinylated lectins. The binding activity of the RPLs and the specificity to a broad range of glycoproteins and glycoconjugates were evaluated and compared to those of equivalent plant-derived lectins. While exhibiting better or similar specificity, RPLs displayed significantly better binding in all cases. The binding mechanisms are explained with particular focus on the role hydrogen bonding plays in the change of specificity for a galactose specific lectin. Furthermore, different sets of RPLs and their plant equivalents were assayed against the different glycoprotein targets to evaluate the analytical parameters of the lectin-glycoprotein interaction. The obtained LoDs reached by the RPLs were lower than those of their plant counterparts apart from one, exhibiting RPL:PL LoD ratios of 0.8, 2.5, 14.2 and 380 for the sets of lectins specific to fucose, α-mannose, ß-galactose and sialic acid, respectively. Such enhancement in analytical parameters of RPLs shows their applicability in protein purification and as bioanalytical tools for glycan analysis and biosensor development.


Assuntos
Medicamentos Biossimilares , Lectinas , Fucose , Glicoproteínas , Manose , Lectinas de Plantas
9.
Sci Justice ; 61(1): 79-88, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33357830

RESUMO

Foot impression evidence recovered from crime scenes can be available in the form of barefoot prints, sock-clad footprints, or as impressions within footwear. In some cases, suspects leave their footwear at the scene of the crime, and the insoles from the footwear can be important in linking a person to the footwear. The application of 3D data-collecting technology is becoming more and more popular within forensic science and has been used to recover footwear impression evidence. The present study is a feasibility study to discover if 3D data capturing devices can be applied to insoles; to capture the footprint impression for measurement using the Gunn method (a method used in forensic podiatry casework). Three different methods of data capture were conducted; Adobe Photoshop, MeshLab, and calipers used directly on the insole. Paired t-tests and Intraclass Correlation Coefficient (ICC) were conducted for all three data capture methods. Seven measurements used in this study were significantly different across all three methods. ICC scores were moderate to excellent for the Photoshop method, poor to good for the 3D method, and moderate to excellent for the Direct method.


Assuntos
Podiatria , Estudos de Viabilidade , , Medicina Legal , Humanos , Sapatos
10.
ACS Omega ; 4(19): 18210-18218, 2019 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-31720522

RESUMO

Gas-hydrate formation has numerous potential applications in the fields of water desalination, capturing greenhouse gases, and energy storage. Hydrogen bonds between water and guest gas are essential for hydrates to form, and their presence in any system is greatly influenced by the presence of either electrolytes or inhibitors in the liquid or impurities in the gas phase. This study considers CH4 as a gaseous impurity in the gas stream employed to form hydrates. In developing gas-hydrate formation processes to serve multiple purposes, CO2 hydrate formation experiments were conducted in the presence of another hydrate-forming gas, CH4, at low concentrations in saline water. These experiments were conducted in both batch and stirred tank reactors in the presence of sodium dodecyl sulfate (SDS) as a kinetic additive at 3.5 MPa and 274.15 K, under isobaric and isothermal conditions. Gas loading was taken as the detection criterion for hydrate formation. It was observed that overall gas loading was hindered by more than 70% with the addition of salts after 2 days. The addition of CH4 to the gas stream led to a further reduction of approximately 30% of gas loading in the batch reactor under quiescent conditions. However, the addition of 100 ppm of SDS improved the gas loading by recovering 34% of the loss observed in volumetric gas loading through the addition of salts and CH4. The introduction of stirring improved the gas loading, and 64% of the loss was recovered through the addition of salts and CH4 after 34 h. The investigation was continued further by substituting CH4 with N2, whereupon accelerated hydrate formation was observed.

11.
J Chem Phys ; 151(12): 124202, 2019 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-31575168

RESUMO

Cavity ring-down spectroscopy (CRDS) is a well-established, highly sensitive absorption technique whose sensitivity and selectivity for trace radical sensing can be further enhanced by measuring the polarization rotation of the intracavity light by the paramagnetic samples in the presence of a magnetic field. In this paper, we highlight the use of this Faraday rotation cavity ring-down spectroscopy (FR-CRDS) for the detection of HO2 radicals. In particular, we use a cold atmospheric pressure plasma jet as a highly efficient source of HO2 radicals and show that FR-CRDS in the near-infrared spectral region (1506 nm) has the potential to be a useful tool for studying radical chemistry. By simultaneously measuring ring-down times of orthogonal linearly polarized light, measurements of Faraday effect-induced rotation angles (θ) and absorption coefficients (α) are retrieved from the same data set. The Faraday rotation measurement exhibits better long-term stability and enhanced sensitivity due to its differential nature, whereby highly correlated noise between the two channels and slow drifts cancel out. The bandwidth-normalized sensitivities are αmin=2.2×10-11 cm-1 Hz-1/2 and θmin=0.62 nrad Hz-1/2. The latter corresponds to a minimum detectable (circular) birefringence of Δnmin=5×10-16 Hz-1/2. Using the overlapping qQ3(N = 4-9) transitions of HO2, we estimate limits of detection of 3.1 × 108 cm-3 based on traditional (absorption) CRDS methods and 6.7 × 107 cm-3 using FR-CRDS detection, where each point of the spectrum was acquired during 2 s. In addition, Verdet constants for pertinent carrier (He, Ar) and bulk (N2, O2) gases were recorded in this spectral region for the first time. These show good agreement with recent measurements of air and values extrapolated from reported Verdet constants at shorter wavelengths, demonstrating the potential of FR-CRDS for measurements of very weak Faraday effects and providing a quantitative validation to the computed rotation angles.

12.
Molecules ; 24(6)2019 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-30889806

RESUMO

Research in the field of hydrate formation requires more focus upon its modelling to enable the researchers to predict and assess the hydrate formation and its characteristics. The main focus of the study was to analyze the deviations induced in various parameters related to hydrate nucleation caused by the choice of different measuring correlations or methods of their sub-components. To serve this purpose under a range of operational conditions, parameters of hydrate nucleation such as rates of nucleation and crystal growth, critical radius of the nucleus, and theoretical induction time for carbon dioxide and methane were considered in this study. From these measurements, we have quantitatively compared the ease of hydrate formation in CO2 and CH4 systems in terms of nucleation while analyzing how various correlations for intermediate parameters were affecting the final output. Values of these parameters were produced under the considered bracket of operational conditions and distributed among six cases using both general and guest-gas specific correlations for gas dissolution and fugacity and their combinations. The isotherms and isobars produced from some of the cases differed from each other considerably. The rate of nucleation in one case showed an exponential deviation with a value over 1 × 1028 at 5 MPa, while the rest showed values as multiples of 106. These deviations explain how sensitive hydrate formation is to processing variables and their respective correlations, highlighting the importance of understanding the applicability of semi-empirical correlations. An attempt was made to define the induction time from a theoretical perspective and derive a relevant equation from the existing models. This equation was validated and analyzed within these six cases from the experimental observations.


Assuntos
Dióxido de Carbono/química , Metano/química , Água/química , Temperatura , Fatores de Tempo
13.
Analyst ; 143(2): 493-502, 2018 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-29271423

RESUMO

The first application of liquid-phase broadband cavity enhanced spectroscopy (BBCEAS) to the measurement of stopped-flow kinetics is reported. The stopped-flow technique is widely used for the study of the kinetics of fast liquid-phase reactions down to millisecond timescales. UV-visible absorption spectroscopy is commonly used as the detection method. Increased sensitivity can potentially allow reactions which are too fast to be measured, to be studied by slowing down the reaction rate through the use of lower concentration of reactants. A simple low cost BBCEAS experimental setup was coupled to a commercial stopped-flow instrument. Comparative standard absorption measurements were also made using a UV-visible double-beam spectrometer as the detector. Measurements were made on the reaction of potassium ferricyanide with sodium ascorbate under pseudo-first order conditions at pH 8 and pH 9.2 A cavity enhancement factor (CEF) of 78 at 434 nm was obtained whilst the minimum detectable change in the absorption coefficient αmin(t), was 1.35 × 10-5 cm-1 Hz-1/2. The kinetic data at pH 9.2 was too fast to be measured using conventional spectroscopy, whilst the BBCEAS measurements allowed 30 fold lower concentration of reactants to be used which slowed down the reaction rate enough to allow the rate constant to be determined. The BBCEAS results showed a 58 fold improvement in sensitivity over the conventional measurements and also compared favourably with the relatively few previous liquid-phase cavity enhanced kinetic studies which have been performed using significantly more complex and expensive experimental setups.

14.
J Forensic Sci ; 63(2): 504-510, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28605021

RESUMO

This study investigates the use of Scanning electron microscopy-energy-dispersive X-ray (SEM-EDX) as a diagnostic tool for the determination of the osseous origin of samples subjected to different temperatures. Sheep (Ovis aries) ribs of two experimental groups (fleshed and defleshed) were burned at temperatures of between 100°C and 1100°C in 100°C increments and subsequently analyzed with the SEM-EDX to determine the atomic percentage of present elements. Three-factor ANOVA analysis showed that neither the exposure temperature, nor whether the burning occurred with or without soft tissue present had any significant influence on the bone's overall elemental makeup (p > 0.05). The Ca/P ratio remained in the osseous typical range of between 1.6 and 2.58 in all analyzed samples. This demonstrates that even faced with high temperatures, the overall gross elemental content and atomic percentage of elements in bone remain stable, creating a unique "fingerprint" for osseous material, even after exposure to extreme conditions.


Assuntos
Cremação , Microscopia Eletrônica de Varredura , Costelas/química , Costelas/ultraestrutura , Espectrometria por Raios X , Análise de Variância , Animais , Cálcio/análise , Antropologia Forense , Magnésio/análise , Modelos Animais , Oxigênio/análise , Fósforo/análise , Ovinos , Temperatura
15.
Sci Justice ; 56(4): 247-55, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27320396

RESUMO

Bloodstains are often encountered at scenes of violent crime and have significant forensic value for criminal investigations. Blood is one of the most commonly encountered types of biological evidence and is the most commonly observed fingerprint contaminant. Presumptive tests are used to test blood stain and blood stained fingerprints are targeted with chemical enhancement methods, such as acid stains, including Acid Black 1, Acid Violet 17 or Acid Yellow 7. Although these techniques successfully visualise ridge detail, they are destructive, do not confirm the presence of blood and can have a negative impact on DNA sampling. A novel application of visible wavelength hyperspectral imaging (HSI) is used for the non-contact, non-destructive detection and identification of blood stained fingerprints on white tiles both before and after wet chemical enhancement using Acid Black 1. The identification was obtained in a non-contact and non-destructive manner, based on the unique visible absorption spectrum of haemoglobin between 400 and 500nm. Results from the exploration of the selectivity of the setup to detect blood against ten other non-blood protein contaminants are also presented. A direct comparison of the effectiveness of HSI with chemical enhancement using Acid Black 1 on white tiles is also shown.


Assuntos
Negro de Amido , Manchas de Sangue , Corantes , Dermatoglifia , Espectrometria de Fluorescência/métodos , Animais , Cavalos , Modelos Animais
16.
Sci Justice ; 56(3): 181-190, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27162016

RESUMO

Blood is one of the most commonly encountered types of biological evidence found at scenes of violent crime and one of the most commonly observed fingerprint contaminants. Current visualisation methods rely on presumptive tests or chemical enhancement methods. Although these can successfully visualise ridge detail, they are destructive, do not confirm the presence of blood and can have a negative impact on DNA sampling. A novel application of visible wavelength reflectance hyperspectral imaging (HSI) has been used for the detection and positive identification of blood stained fingerprints in a non-contact and non-destructive manner on white ceramic tiles. The identification of blood was based on the unique visible absorption spectrum of haemoglobin between 400 and 500 nm. HSI has been used to successfully visualise ridge detail in blood stained fingerprints to the ninth depletion. Ridge detail was still detectable with diluted blood to 20-fold dilutions. Latent blood stains were detectable to 15,000-fold dilutions. Ridge detail was detectable for fingerprints up to 6 months old. HSI was also able to conclusively distinguish blood stained fingerprints from fingerprints in six paints and eleven other red/brown media with zero false positives.


Assuntos
Manchas de Sangue , Dermatoglifia , Análise Espectral/métodos , Hemoglobinas/análise , Humanos , Processamento de Imagem Assistida por Computador
17.
Sci Justice ; 56(3): 191-200, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27162017

RESUMO

Biological samples, such as blood, are regularly encountered at violent crime scenes and successful identification is critical for criminal investigations. Blood is one of the most commonly encountered fingerprint contaminants and current identification methods involve presumptive tests or wet chemical enhancement. These are destructive however; can affect subsequent DNA sampling; and do not confirm the presence of blood, meaning they are susceptible to false positives. A novel application of visible wavelength reflectance hyperspectral imaging (HSI) has been used for the non-contact, non-destructive detection and identification of blood stained fingerprints across a range of coloured substrates of varying porosities. The identification of blood was based on the Soret γ band absorption of haemoglobin between 400 nm and 500 nm. Ridge detail was successfully visualised to the third depletion across light coloured substrates and the stain detected to the tenth depletion on both porous and non-porous substrates. A higher resolution setup for blood stained fingerprints on black tiles, detected ridge detail to the third depletion and the stain to the tenth depletion, demonstrating considerable advancements from previous work. Diluted blood stains at 1500 and 1000 fold dilutions for wet and dry stains respectively were also detected on pig skin as a replica for human skin.


Assuntos
Manchas de Sangue , Dermatoglifia , Análise Espectral/métodos , Hemoglobinas/análise , Humanos , Processamento de Imagem Assistida por Computador , Porosidade , Propriedades de Superfície
18.
Anal Chem ; 88(10): 5264-70, 2016 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-27089516

RESUMO

We report on the first detailed use of broadband cavity enhanced absorption spectroscopy (BBCEAS) as a detection system for immunoassay. A vertical R ≥ 0.99 optical cavity was integrated with a motorized XY stage, which functioned as a receptacle for 96-well microtiter plates. The custom-built cavity enhanced microplate reader was used to make measurements on a commercially available osteocalcin sandwich ELISA kit. A 30-fold increase in path length was obtained with a minimum detectable change in the absorption coefficient, αmin(t), of 5.3 × 10(-5) cm(-1) Hz(-1/2). This corresponded to a 39-fold increase in the sensitivity of measurement when directly compared to measurements in a conventional microplate reader. Separate measurements of a standard STREP-HRP colorimetric reaction in microtiter plates of differing optical quality produced an increase in sensitivity of up to 115-fold compared to a conventional microplate reader. The sensitivity of the developed setup compared favorably with previous liquid-phase cavity enhanced studies and approaches the sensitivity of typical fluorometric ELISAs. It could benefit any biochemical test which uses single pass absorption as a detection method, through either the label free detection of biologically important molecules at lower concentrations or the reduction in the amount of expensive biochemicals needed for a particular test, leading to cheaper tests.


Assuntos
Imunoensaio/métodos , Osteocalcina/análise , Anticorpos/imunologia , Colorimetria , Humanos , Imunoensaio/instrumentação , Limite de Detecção , Osteocalcina/imunologia
19.
J Forensic Sci ; 61(1): 153-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26275238

RESUMO

This study investigated the effect of soft tissue and different exposure times on the prediction of burning temperatures of bone when using Fourier transform infrared spectroscopy (FTIR). Ovis aries rib bones were burnt at different temperatures and for varying time intervals. Results of a linear regression analysis indicated that burn temperatures can be predicted with a standard error of ±70 °C from defleshed bone spectra. Exposure time does not have a significant impact on prediction accuracy. The presence of soft tissue has a significant impact on heat-induced changes of the bone matrix in low (<300 °C) as well as high temperatures (>800 °C), slowing down combustion in the former and accelerating it in the latter (p < 0.05). At medium temperatures, no significant difference was noted. These results provide forensic investigators a new perspective with which to interpret the results of crystallinity measures derived from burnt bone.


Assuntos
Incêndios , Costelas/patologia , Espectroscopia de Infravermelho com Transformada de Fourier , Temperatura , Animais , Queimaduras , Patologia Legal , Modelos Lineares , Ovinos
20.
Sci Justice ; 55(4): 219-38, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26087870

RESUMO

Fingerprints have a key role in criminal investigations and are the most commonly used form of evidence worldwide. Significant gaps remain however, in the understanding of fingerprint chemistry, including enhancement reaction mechanisms and the effect of environmental variables and time on composition. Determining the age of a fingerprint is also a relatively unexplored area. A successful method, with reliable and quantitative estimates, would have numerous advantages. Previous unreliable methods have predominantly focused on enhancement success based on physical and chemical changes. This review explores variations in composition due to donor characteristics and environmental variables, and identifies gaps for further research. We also present a qualitative and quantitative summary of the effect of time on composition. Kinetics are presented where known, with summary schematics for reaction mechanisms. Previous studies exploring methods for determining the age of a fingerprint are also discussed, including their advantages and disadvantages. Lastly we propose a potentially more accurate and reliable methodology for determining fingerprint age based on quantitative kinetic changes to the composition of a fingerprint over time.


Assuntos
Dermatoglifia , Sebo/química , Aminoácidos/análise , Exposição Ambiental , Fluorescência , Glucose/análise , Humanos , Umidade , Luz , Lipídeos/análise , Proteínas/análise , Esqualeno/análise , Temperatura , Fatores de Tempo , Oligoelementos/análise , Vácuo